Running accuracy constitutes the acceptable values for inner and outer ring radial runout and axial runout, inner ring side runout, and outer ring outer diameter runout.


| Characteristic tolerance | Measurement method | |
| Inner ring radial runout (Kia) |
|
For inner ring radial runout, record the total indicator reading (TIR). |
| Outer ring radial runout (Kea) |
|
For outer ring radial runout, record the total indicator reading (TIR) after one revolution. |
| Inner ring axial runout (Sia) |
|
For inner ring axial runout, record the total indicator reading (TIR) after rotating the inner ring one revolution. |
| Outer ring axial runout (Sea) |
|
For outer ring axial runout, record the total indicator reading (TIR) after rotating the outer ring one revolution. |
| Inner ring side runout with bore (Sd) |
|
For inner ring side runout with bore, record the total indicator reading (TIR) after rotating the inner ring one revolution with a tapered mandrel. |
| Outer ring outside surface inclination (SD) |
|
For outer ring outside surface inclination, record the total indicator reading (TIR) after aligning the ring with the reinforcing plate and rotating it one revolution. |